At present position:Home page > Catalogue >WIN-9G(P)F |
| ■ WIN-9G(P)F Strong function |
| |
Trait
Most ideal for energy saving in compressor, sequeezing engine, pump and blower
SPWM control
Stable output operating for low speed rating torque
Follow load changing fast, offer high efficient output voltage, suitable for different loads’ V/F feature and self adjusting
Internal RS-485 communicate interface, support MODBUS protocol
Advanced auto torque compensation design, optimize the system performance
Energy saving operating mode for option to make motor work more efficiently
28 kinds of protect function and alarm function
Internal PID adjuster that make adjusting convenient
Multiple online monitoring function and online adjusting function |
 |
|
| |
WIN-9G(P)F Series keyboard layout and function introduction |
 |
Monitor content introduction
| Fref:Frequency set/monitor |
Fout:Output frequency monitoring |
lout:Output current monitoring |
kWout:Output power monitoring |
| F/R:Operating direction set/read out |
Montr:Monitoring items selection |
Accel:Speed up time |
Deccel:Speed down time |
| Vmtr:Motor rating voltage set/read out |
V/F:V/F curve set/read out |
Fgain:Frequency added value set/read out |
Fbais:Given frequency offset set/read out |
| FLA:Motor rating current set/read out |
PID:PID control function selection |
kWsav:Energy saving control function switch |
PRGM:Parameter set/read out |
|
 |
Control circuit terminal |
 |
|
Controling return circuit terminal function |
| |
| Type |
Terminal |
Function Name |
Description |
| Control signal |
FOR |
Forward run / stop |
Forward run when closed, stop when open |
| X1 |
Reverse run / stop |
Reverse run when closed, stop when open |
Multifunction contact input
(P035 ~ 039) |
| X2 |
External fault input |
Fault when closed, normal when open |
| X3 |
Fault reset |
Reset when closed |
| X4 |
Multi-step speed reference 1 |
Effective when closed |
| X5 |
Multi-step speed reference 2 |
Effective when closed |
| COM |
Switch input common terminal |
-- |
| Analog input signal |
+12V |
+12V power supply output |
模拟指令+12V电源 |
| VG |
Frequency reference input voltage |
0~10V/100% |
P042=0:VG effective
P042=1:IG effective |
| IG |
Frequency reference input current |
4~20mA/100% |
| GND |
Signal wire shield sheath connecting terminal |
-- |
| Switch output signal |
TA2 |
Operating signal(normal open connector) |
Closed when operating |
Multifunction contact junction output (P041) |
| TC2 |
| TA1 |
Error contact output |
Fault when TA1 and TC1 close
Fault when TB1 and TC1 open |
Multifunction contact junction output (P040) |
| TB1 |
| TC1 |
| Analog output signal |
FM |
Output frequency |
0~10V/100% frequency |
Multifunction analog value monitoring (P048) |
| GND |
Analog input common ground |
|
|
|
|
|
|
|
 |
Standard connection diagram |
 |
 |
Installation Dimension |
|
| Fig.3 |
 |
| Fig.4 |
 |
 |
| Fig.5 |
 |
 |
WIN-9G(P)F - T4(hangs type)Install size |
| Specification |
W |
W1 |
H |
H1 |
H2 |
D |
D1 |
D2 |
d |
fig. |
| WIN-9_F-1R5~3R7T4 |
150 |
130 |
252 |
205 |
-- |
167 |
175 |
109 |
5.5 |
2 |
| WIN-9_F-5R5~7R5T4 |
190 |
170 |
290 |
260 |
-- |
187 |
195 |
105 |
5.5 |
2 |
| WIN-9_F-011~015T4/9P-018T4 |
245 |
200 |
410 |
390 |
367 |
240 |
245 |
140 |
7 |
3 |
| WIN-9_F-018~030T4 |
278 |
200 |
550 |
530 |
490 |
250 |
260 |
155 |
10 |
3 |
| WIN-9_F-037T4 |
348 |
200 |
550 |
530 |
490 |
250 |
260 |
185 |
10 |
3 |
| WIN-9_F-045T4/9P-055T4 |
348 |
240 |
700 |
680 |
640 |
335 |
345 |
215 |
10 |
3 |
| WIN-9_F-055~075T4 |
375 |
300 |
785 |
760 |
717 |
335 |
345 |
240 |
12 |
3 |
| WIN-9_F-093~132T4/9P-160T4 |
530 |
420 |
920 |
890 |
852 |
335 |
345 |
250 |
12 |
3 |
| WIN-9_F-160~200T4 |
695 |
580 |
1140 |
1110 |
1072 |
335 |
345 |
250 |
14 |
3 |
| WIN-9_F-220~400T4 |
820 |
600 |
1334 |
1300 |
1260 |
450 |
460 |
240 |
14 |
3 |
|
WIN-9G(P)F - T4(cabinet type)Install size |
| Specification |
W |
W1 |
W2 |
H |
H1 |
D |
D1 |
D2 |
D3 |
d |
fig. |
| WIN-9_F-160~200T4 |
700 |
40 |
620 |
1800 |
1760 |
455 |
465 |
40 |
345 |
18 |
4 |
| WIN-9_F-220~400T4 |
820 |
40 |
690 |
1800 |
1760 |
455 |
465 |
40 |
345 |
18 |
4 |
| WIN-9_F-500T4 |
1100 |
75 |
950 |
2200 |
2160 |
455 |
465 |
40 |
345 |
18 |
4 |
| WIN-9_F-560~800T4 |
1640 |
40 |
720 |
1800 |
1760 |
455 |
465 |
40 |
345 |
18 |
5 |
| WIN-9_F-1000T4 |
2200 |
75 |
950 |
2200 |
2160 |
455 |
465 |
40 |
345 |
18 |
5 |
|
| |
| Remarks:T4 = 380V ; T6 = 660~690V |
 |